Circuit Breaker ACB 3P 1600A 55kA NADER | NDW3-2500HU

Rated current (In)1600A
Rated voltage (Ue)220/230/240 Vac, 380/400/415 Vac, 440/480 Vac, 660/690 Vac, 800 Vac, 1000 Vac, 1140 Vac
Rated frequency50 / 60 Hz
StandardIEC 60947-2, GB/T 14048.2

[button text=”Download File” color=”primary” style=”outline” size=”large” radius=”10″ link=”https://drive.google.com/file/d/1k8MCM0OlZYTPu5cPdr2RvSm40owrNHvu/view?usp=sharing” target=”_blank”]

Additional information

Hotline / Zalo: 08.9811.0068

PRODUCT INFORMATION

NDW3 ACB Series

The NDW3 ACB series is used for infrequent circuit switching with a frequency of 50Hz / 60Hz, a rated operating voltage of AC690V, and a rated operating current of 1250A, as well as occasional motor starting. The circuit breaker features an overload warning function without disconnection. In the event of a line overload, the circuit breaker will not disconnect but will issue an overload signal to ensure continuous power supply.

The product can be used for up to 8 hours at 1.3 times the rated current, maintaining performance after cooling. The circuit breaker can replace thermal relay warning solutions; with overload, short circuit, and overvoltage protection functions, it can protect the wiring and electrical equipment from damage.

Highlight features:

– There are four types: type C (basic), type L (standard), type M (higher breaking capacity), and type H (high breaking capacity) according to the rated short-circuit breaking capacity.
– Smaller size, better circuit-breaking capability.
– Efficient arc extinguishing, vibration resistance.
– Enclosed accessories can be used for quick installation of the circuit breaker and promptly meet user requirements without any adjustments.

Technical specifications:

ModelNDW3-2500HU
Rated current (In)1600A
Rated operational current of the pole100% In
Rated operational voltage (Ue)220/230/240 Vac, 380/400/415 Vac, 440/480 Vac, 660/690 Vac, 800 Vac, 1000 Vac, 1140 Vac
Rated frequency (f)50 / 60 Hz
Rated insulation voltage (Ui)1250V
Rated impulse withstand voltage (Uimp)12 kV
Number of poles3 / 4
Circuit breaking time< 30ms
Closing time< 70ms
Breaking typeHU
Maximum short-circuit current (Icu)AC220~415V
AC440V/480V/660V/690V
AC800V60 kA
AC1000V55 kA
AC1140V50 kA
Actual short-circuit current (Ics)AC220~415V
AC440V/480V/660V/690V
AC800V60 kA
AC1000V55 kA
AC1140V50 kA
Rated impulse withstand current when closing test (Icm)AC220~415V
AC440V/480V/660V/690V
AC800V132 kA
AC1000V121 kA
AC1140V110 kA
Short-circuit withstand capability of the circuit breaker (Icw) – 1sAC220~415V
AC440V/480V/660V/690V
AC800V60 kA
AC1000V55 kA
AC1140V50 kA
Operational efficiencyElectrical endurance (number of operations)

Operating frequency (20 operations/hour)

AC220~415V11.500
AC440V/480V/660V/690V10.000
AC800V5.000
AC1000V/1400V3.000
Mechanical endurance (number of operations)

Operating frequency (60 operations/hour)

Maintenance-free15.000
Regular maintenance30.000
Setting modeFixed, withdrawable
Main circuit wiring methodHorizontal busbar, vertical busbar, horizontal extended busbar, vertical extended busbar, mixed (top horizontal, bottom vertical), mixed (top vertical, bottom horizontal)
Dimensions (Width x Depth x Height)Fixed type 3P368 x 309,5 x 394 mm
Fixed type 4P463 x 309,5 x 394 mm
Withdrawable type 3P375 x 400 x 432 mm
Withdrawable type 4P470 x 400 x 432 mm
WeightFixed type 3P50 kg
Fixed type 4P62,3 kg
Withdrawable type 3P87,4 kg
Withdrawable type 4P106,7 kg